LR97D25BMain Device short name LR97 Product or component type Electronic overcurrent relay Device application Protection Relay application Overload Imax > Isetting Locked rotor, mechanical jamming I > 3 x Isetting Sensitivity to phase failure Product compatibility LC1D09 D38 Network type AC DC [Us] rated supply voltage 24 V AC DC Thermal protection adjustment range 525 A [Ue] rated operational voltage 600 V AC 50 60 Hz for power circuit conforming to CSA 600

Main
Device short name LR97
Product or component type Electronic overcurrent relay
Device application Protection
Relay application Overload Imax > Isetting
Locked rotor, mechanical jamming I > 3 x Isetting
Sensitivity to phase failure
Product compatibility LC1D09...D38
Network type AC
DC
[Us] rated supply voltage 24 V AC/DC
Thermal protection adjustment range 5…25 A
[Ue] rated operational voltage 600 V AC 50/60 Hz for power circuit conforming to CSA
600 V AC 50/60 Hz for power circuit conforming to UL
690 V AC 50/60 Hz for power circuit conforming to IEC 60947-4-1
Quantity per set Set of 10
Complementary
Network frequency 50...60 Hz
Mounting support Direct on contactor
Rail
Tripping threshold 5...21 A
Surge withstand 6 kV conforming to IEC 61000-4-5
Contacts type and composition 1 C/O
[Ith] conventional free air thermal current 3 A for control circuit
Protection type BS fuse 3 A - for control circuit
GB2 circuit breaker 3 A - for control circuit
GG fuse 3 A - for control circuit
Maximum power 28 W at 110 V DC conforming to IEC 60947
28 W at 220 V DC conforming to IEC 60947
55 W at 24 V DC conforming to IEC 60947
55 W at 48 V DC conforming to IEC 60947
140 VA at 48 V AC conforming to IEC 60947
360 VA at 110 V AC conforming to IEC 60947
360 VA at 220 V AC conforming to IEC 60947
70 VA at 24 V AC conforming to IEC 60947
[Ui] rated insulation voltage Power circuit: 600 V conforming to CSA
Power circuit: 600 V conforming to UL
Power circuit: 690 V conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage 6 kV
Phase failure sensitivity < 3 s
Reset Automatic reset 120 s fixed
Electrical by interruption of power supply for minimum 0.1 s
Manual reset
Time range 0.2...10 s - O-time knob
0.3...10 s - O-time knob
0.5..30 s - D-time knob
Signalling function 2 LEDs
Connections - terminals Control circuit: cable 1 x 1…25 mm²flexible with cable end
Control circuit: cable 1 x 1…25 mm²flexible without cable end
Power circuit: cable 1 x 1…4 mm²flexible with cable end
Power circuit: cable 1 x 1.5…10 mm²flexible without cable end
Power circuit: lug-clamp 1 x 1…4 mm²flexible with cable end
Power circuit: lug-clamp 1 x 1.5…10 mm²flexible without cable end
Control circuit: cable 2 x 1…25 mm²flexible with cable end
Control circuit: cable 2 x 1…25 mm²flexible without cable end
Control circuit: lug-clamp 1 x 1…25 mm²flexible with cable end
Control circuit: lug-clamp 1 x 1…25 mm²flexible without cable end
Control circuit: lug-clamp 2 x 1…25 mm²flexible with cable end
Control circuit: lug-clamp 2 x 1…25 mm²flexible without cable end
Tightening torque Control circuit: 0.6...1.2 N.m on lug-clamp
Power circuit: 2 N.m on cable
Height 67.5 mm
Width 45 mm
Depth 67.5 mm
Net weight 0.172 kg
Environment
Standards IEC 60947
IEC 60255-6
Product certifications UL
GOST
CSA
Protective treatment TH conforming to IEC 60068
IP degree of protection IP20 conforming to IEC 60529
Ambient air temperature for operation -25…60 °C conforming to IEC 60947-4-1
Ambient air temperature for storage -30…80 °C
Operating altitude 2000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Shock resistance 15 gn 11 ms conforming to IEC 60068-2-7
Vibration resistance 4 gn conforming to IEC 60068-2-6
Dielectric strength 2 V 50 Hz conforming to IEC 60255-5
Resistance to electrostatic discharge 6 kV in indirect mode
8 kV in air
Resistance to radiated fields 10 V/m level 3
Resistance to fast transients 2 kV
Disturbance radiated/conducted 10 V conforming to EN 61000-4-6
Class A conforming to EN 55011
Offer Sustainability
EU RoHS Directive Compliant
EU RoHS Declaration
Toxic heavy metal free Yes
Mercury free Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS declaration
Circularity Profile
End of Life Information
WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Contractual warranty
Warranty 18 months
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 42871584635

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.2 ★★★★★
Based on 2224 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
D
Verified Purchase
Dustin
Lake Worth, US
★★★★★ 5
Works if you need help. Not a miracle in a bottle.
Size: 1 Count (Pack of 1)
It has worked every time I've used this product. Won't fix a damage catalytic converter but will help you pass the test if your car almost passed.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 28, 2026
L
Verified Purchase
Leslie Price
Belleville, US
★★★★★ 5
Worked like a charm.
Size: 1 Count (Pack of 1)
Used it as directed. Down to an eighth of a tank. Poured it in and added enough gas to get back to one half a tank. Wanted to get it mixed in really well. Immediately jumped on the interstate and ran 75 MPH for 40 miles. Stopped and filled the tank and when I restarted the engine, the light was off. Coincidence? Not a chance. Light had been on continuously for weeks. AutoZone said I needed a catalytic converter. Nope. One thing I found out the hard way. If your gas filler has a flap at the top, make sure it is easy to push aside. Mine had a little release button near the top that the filler hose would depress before the flap would release. Dumped the first bottle right on the ground. Twelve bucks wasted. No one to blame but me, I guess. Still a bargain, even at twice the price.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on February 17, 2026
B
Verified Purchase
Brenda A DeRouen
Alexandria, US
★★★★★ 1
Before use on March 15 two days later March 17 engine light still on
Size: 1 Count (Pack of 1), Size: 1 Count (Pack of 1)
I read the specs on this product and it was guaranteed to cleanse as well as turn engine light off in vehicle. I received it March 14.2026 and used it on March 15.2026 I took a picture on Sunday before I entered it into the gas tank engine light was on at that time. Today is March 17.2026 and engine light is still on. The truck was driven for one hour on the 15th 45 minutes on the 16th and 50 minutes on 17 March. Still the engine light is on. Got home parked the vehicle took a picture again to show engine light is still on product guaranteed it was shut it off, but unfortunately product does not work.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on March 17, 2026
A
Verified Purchase
Amazon Customer
Battle Creek, US
★★★★★ 4
Good stuff
Size: 1 Count (Pack of 1)
I've used and it's worked for emissions for me and that's with having check engine light on..use stuff,drive around a bit,clear code drive to emissions and should b good unless got serious problems. It's good to use 1 or 2 times a yr if high mileage vehicle.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on January 1, 2025
A
Verified Purchase
A.U.
Lexington, US
★★★★★ 5
It works!
Size: 1 Count (Pack of 1)
My 2005 Jetta failed the inspection and my mechanic said (after clearing the engine light) that I should drive the car for 20 min highway and 20 local. We've tried that the whole day but out of three lights on his device only 1 went away. Next day the light engine came back. After not being happy with the explanation offered by him (a family friend) that I should keep driving it until we get lucky I went online and found CRC 05063. Followed the instruction (one bottle on full tank of gas). Before my tank was under 3/4, engine light went off!! At half tank I went and did the inspection - IT PASSED! I am really impressed! Update August 2015! I have been using this product for 2-3 years now and if it is not working for you please read. In July I have used the first bottle and took my 2005 Jetta for inspection. It failed. Ordered a second bottle and it failed again. My mechanic said keep driving. Did 200 miles in one day and nothing. Decided to take matters in my own hands and ordered Autel MaxiScan MS300 ($18, it allows you to read and delete codes). There were two faults - EVAP and 2nd something about Oxygen. Went online and this is the first time I heard about driving cycles. These are steps that you have to follow so that your car's computer can start measuring all the parameters needed for the test. Driving cycles are not exact science but I tried to follow the instructions as much as I could and after just 20 minutes (10min city and 10min highway) ALL the parameters were set and I passed the emission test with flying colors! So, just before you give a comment about CRC like "tried and didn't work" be aware that there are other things you have to take into account.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on July 1, 2013

recommand products