SKU: 73850137652

HKM-904467 Dynamic 12-Lead 24-Hour ECG EKG Holter Monitor with PC Analysis Software

Sale price$227.25 Regular price$252.50
Save 10%

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 9 - Jul 14

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

HKM-904467 Dynamic 12-Lead 24-Hour ECG EKG Holter Monitor with PC Analysis SoftwareIntroducing the HKM 904467 Dynamic 12 Lead 24 Hour ECG EKG Holter Monitor with PC Analysis Software, a comprehensive solution designed for continuous cardiovascular monitoring. This state of the art device leverages a 12 lead system per international standards, allowing for the consistent recording of ECG waveforms over a full 24 hour period. This monitor is particularly suitable for use in medical institutions and community health settings, providing

Introducing the HKM-904467 Dynamic 12-Lead 24-Hour ECG EKG Holter Monitor with PC Analysis Software, a comprehensive solution designed for continuous cardiovascular monitoring. This state-of-the-art device leverages a 12-lead system per international standards, allowing for the consistent recording of ECG waveforms over a full 24-hour period.

This monitor is particularly suitable for use in medical institutions and community health settings, providing physicians with the essential tools to analyze and interpret vital heart metrics effectively. The HKM-904467 ensures a synchronized analysis of 12 leads, offering the flexibility to select any channel as the primary for in-depth examination. This functionality enhances the accuracy of QRS waveform identification while eliminating distortion, making it easier for healthcare professionals to diagnose various heart conditions.

Equipped with over 10 diagnostic templates and customizable modules, this monitor can identify a wide array of pathological waveforms, such as atrial premature beats and ventricular fibrillation. Its advanced atrial fibrillation analysis capabilities provide physicians the option to conduct auto or manual assessments, delivering more precise results.

The HKM-904467's robust analysis features extend to pacemaker function, supporting all pacemaker types like AAI, VVI, and DDD. Users can quickly review both single and full-lead ECGs with its fast review analysis function, ensuring timely access to critical data. Furthermore, the monitor includes analysis functions for 5-minute, 1-hour intervals, and overall heart rate variability, enhancing the depth of cardiac assessments.

For convenience, the device allows one-key printing of reports, streamlining the process of sharing findings with patients or colleagues. Unique analysis capabilities include predictive assessments for myocardial infarction via "HRT" analysis, as well as critical indices like T-Wave alternation, QT dispersion, and more, further increasing the monitor's utility in clinical environments.

Powered by a standard “AAA” alkaline battery and featuring a USB2.0 interface, the HKM-904467 is both user-friendly and high-performance. With meticulous attention to accuracy and stability, this monitor is a reliable choice for anyone seeking rigorous heart health monitoring.

Choose the HKM-904467 Dynamic 12-Lead 24-Hour ECG EKG Holter Monitor to enhance your patient care and cardiac evaluations.

Introduction

Dynamic ECG Systems adopt 12-lead system of international standard, which can continuously record ECG waveform for 24-hour and analyze ECG waveform by the PC software. It is applicable for use in medical institution and community.


Function

1)Adopt 12-lead system of international standard, continuously record ECG waveform for 24-hour.
2)Sync analysis for 12-lead, and any channels can be selected as the main analysis channel, which ensures that QRS waveform can be found accurately, and no distortion.
3)With more than 10 templates(such as atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, etc.) and many user-defined modules, which can almost distinguish any kind of pathologic waveforms.
4)Flexible atrial fibrillation analysis, which ensures that physicians can use the whole or segmented AUTO/manual analysis, more accurate in atrial fibrillation analysis.
5)All pacemakers(such as AAI, VVI, DDD etc.) can be analyzed by the powerful pacemaker analysis function.
6)Single or full-lead ECG in any time bucket can be reviewed by the fast review analysis function.
7)With analysis functions for 5-minute, 1-hour and whole heart rate variability.
8)One-key print, convenient and fast to print the reports.
9)The death risk in patients with myocardial infarction can be predicted by the "HRT" analysis function.
10)“T-Wave alternation” is an important index to predict the malignant arrhythmia and sudden cardiac death.
11)With QTD(QT dispersion), VCG(vector cardiogram), VLP(ventricular late potential) and TVCG(time vector cardiogram) analysis modules, more valuable in analysis report.


Performance

1)Lead: standard 12-lead
2)Power supply: one “AAA” alkaline battery
3)Interface: USB2.0
4)Input impedance: ≥10MΩ
5)CMR: ≥60dB
6)Gain accuracy: At all possible gain settings, the maximum amplitude error of the output is ±10%
7)Gain stability: One minute after energizing the device, the gain change in stable ambient conditions shall not exceed 3% over a 24h period.
8)System noise: ≤50µVp-p
9)Multichannel crosstalk: ≤0.2mV
10)Frequency response: The amplitude response to sinusoidal signals within the frequency range 0.05Hz to 40Hz shall be between the +3dB to -3dB of the response at 5 Hz.
11)Minimum measure signal: 50 µV
12)Timing accuracy: the overall error during 24h shall not exceed 30s.


Accessories

Lead cable (1 set)
ECG electrode (1 bag)
USB cable(1)
Software(1)
Bag(1)
User manual(1)


Physical characteristic

Recorder dimension: 81mm(L) × 60mm(W) × 22mm(H)
Weight: about 61.5g(without batteries)


Optional configuration

Refer to BOM.


Certification

CE, FDA

Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 73850137652

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.1 ★★★★★
Based on 1936 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
G
Verified Purchase
GREGORY
Louisville, US
★★★★★ 5
GOOD DEAL
Sun protection factor: 50 Sun Protection Factor (SPF), Size: 7 Fl Oz (Pack of 2)
First time using this product, and it has performed as advertised. Easy to apply and stands up very well during my runs and bike rides. Overall a good product and a definite recommend.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 13, 2026
A
Verified Purchase
Amazon Customer
Fort Morgan, US
★★★★★ 5
N/A
Sun protection factor: 50 Sun Protection Factor (SPF), Size: 7 Fl Oz (Pack of 2)
Very good Product, works well...
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 16, 2026
M
Verified Purchase
Mildred Martinez
Omaha, US
★★★★★ 5
Price and sp number.
Sun protection factor: 50 Sun Protection Factor (SPF), Size: 7 Fl Oz (Pack of 2)
Excellent cream: not greasy and good concentration.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 16, 2026
T
Verified Purchase
Terry McVay
Bozeman, US
★★★★★ 4
good buy
Sun protection factor: 50 Sun Protection Factor (SPF), Size: 7 Fl Oz (Pack of 2)
what can you say. Works as advertised
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 19, 2026
A
Verified Purchase
Amazon Customer
Dallas, US
★★★★★ 5
works
Sun protection factor: 50 Sun Protection Factor (SPF), Size: 7 Fl Oz (Pack of 2)
Worked Great - no burn
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on February 12, 2026

recommand products